[B]Product Selection[B]
All domnick hunter condensate drains & oil/water separators are sized based upon the maximum condensate volume produced at a given set of ambient conditions. Should the conditions differ from those shown below, please contact our Technical Sales Department for correct model selection.
[B]IMPORTANT NOTE[B]
The performance of the oil/water separator and the economic service life of the activated...
Read more.
[B]Product Selection[B]
All domnick hunter condensate drains & oil/water separators are sized based upon the maximum condensate volume produced at a given set of ambient conditions. Should the conditions differ from those shown below, please contact our Technical Sales Department for correct model selection.
[B]IMPORTANT NOTE[B]
The performance of the oil/water separator and the economic service life of the activated carbon is dependent upon the degree of oil dispersion and emulsification of the incoming condensate. The frequency of activated carbon pack changes will therefore depend upon the following factors.
Compressor type and capacity, lubricant used, condensate drainage method, ambient temperature, relative humidity, pressure and condensate drainage method. Static oil/water separators of this type will not totally separate oils that are soluble in water.
For stable emulsions, use the domnick hunter EMS range of Membrane Emulsion Separators.
[B]Ambient Temperature at Compressor Inlet:[B] 25°C (77°F)
[B]Relative Humidity at Compressor Inlet:[B] 65%
[B]Compressor Discharge Temperature:[B] 35°C (95°F)
[B]System Pressure:[B] 7 bar g (102 psi g)
[B]Refrigeration Dryer Dewpoint:[B] 2°C (36°F)